EXTRACTED TEXT FROM: Instractions for Mini 295 Beam.docx


LED operating instructions for stage lighting equipment





                       


(Please read the instructions carefully and carefully before using the product)
For proper and safe use, read the instructions carefully before installing and using the product. This specification contains important installation and application information, please strictly follow the instructions when installing and operating the product. At the same time, please keep this instruction manual properly.
Our 230W beam lamp uses a new and beautiful high-temperature resistant metal body. This product strictly follows the CE standard for design and production, in line with the international standard DMX512 signal protocol, can be used separately for control, can also be used online, with fast rotation, low noise, powerful features, suitable for small and medium-sized concerts, theaters, studios, nightclubs and bars and other places,
Please remove the package carefully, check whether the product is damaged during transportation, and check whether the following contents are complete.
          
Beam lamp- - - - - - - - -1 set             Instruction manual- - - - - - - -1 version
          Power cord- - - - - - - - -1 piece             Signal line- - - - - - - - -1 bar                 
This product is a good product before delivery. In order to keep the product in good condition and ensure safe operation, users should follow the safety matters and the instructions.
Important: Damage caused by not following this instruction is not covered by the warranty. The supplier is not responsible for the product problems arising from this.
If the product has been exposed to extreme unstable temperature (e. g. after transportation), do not power the product immediately because water drops due to temperature changes may damage the product. Please use it after the product has returned to the normal temperature.
This product can be used in the voltage range of 90-240V, and is used for indoor products. Please confirm that the voltage used is not above the tolerable range of the product!! The power plug must be plugged into a protective class I socket. Green or tea-cyan conductors must be grounded.
Please check the product and the power cord frequently. Ensure that the power cord is not folded or damaged and not connected to other wires! Special attention is required when connecting the power cord or the related wiring. Unplug the power supply without using the product or before cleaning.
Before using the product, please be familiar with the operation function of the product. Please do not expose children or no professionals to the product. Please do not shake this product. Do not use brute force when installing or operating the product. Do not allow unprofessionals to operate the product. Most of the damage is caused by an unprofessional operation.
The product is not equipped with relevant repair accessories. The maintenance and repair of the products can only be carried out by professionals!
Please do not change this product without authorization, otherwise the product may be damaged, so the damage caused is not covered by the warranty. Also, unprofessional operations can lead to short circuits, burns or electric shocks, and so on.




DMX512 Connection of the signal:
This lamp uses DMX512 signal control mode, and the control signal of each lamp is in parallel. When connecting the signals of multiple lamps, it is best to use dual-core shielding cable. When connecting, each lamp is connected through the DMX signal jack (Canon seat) INPUT (input) and OUTPUT (output). The 3-core XLR plug terminal of the signal line connecting the lamp must correspond to each other. When connecting the lamp signal, it is recommended to use the DMX signal terminal. It is possible to destroy the control signal due to electrical noise. The DMX signal terminal is a 120 ohm 1W resistance between the 2 and 3 feet of an XLR plug and connects it to the OUTPUT (output) jack of the last lamp.
Calculation method of lamp starting address code:
The starting address code of the current lamp is equal to (the starting address code of the previous lamp) + (number of channels of the lamp) description:
1: Start address code value of the first lamp A001.
2: The basic number of controller should be greater than or equal to the total number of lighting channels.
3: Note: when any controller is used, each lamp must have its own starting address code. If the starting address code of the first lamp is set A001, the pass number of the lamp is 16 CH; then the starting address code of the second lamp is set to A017; the starting address code of the third lamp is set to A033; and so on, (this setting mode should be determined by different console).

Product Parameter:
Input voltage: AC100V-220V 50 / 60Hz
Power: 450W
Color plate: 12 colors + white light
Colorful color: six-color plate
Fixed pattern: 13 patterns + white light
Prism: a single prism
Aization: six color rainbow + atomization integration
Horizontal / vertical: 540° horizontal scan, 270° vertical scan
Display interface: color screen 1.8 inch button, 180° reverse display can be switched in Chinese and English
Protection level: IP20

Menu Action Settings
primary menu
Submenu one
Function Settings
Functional profile
DMX address

1-512

System Settings
Show upside down
normal
.


overturn


Language setting
the Chinese language



English


channel pattern
20CH


running mode
DMX



sound control



voluntarily


Electronic lighting
close



open


The bulb default
Turn on _ Close


Bulb control
illume


optimal path
Turn on _ Close


Horizontal reverse
close



open


Vertical reverse
close



open


XY velocity
low speed



intermediate speed



fast


Optical coupling detection
close



open


Return to the superior
▲

information services
total time
0-9999


Light bulb time
0-9999


binding hours
0-9999


display software
Vx001


XY software
Vx001


Small motor software
Vx001


Return to the superior
▲

Channel control
Color hovering
0-255


stroboflash
0-255


aiming"
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


atomization
0-255


focus
0-255


Horizontal rotation
0-255


Horizontal fine-tuning
0-255


vertical turn
0-255


Vertical fine-tuning
0-255


reset
0-255


light up
0-255


XY velocity
0-255


Color disk speed
0-255


Zoom speed
0-255


pattern velocity
0-255


Return to the superior
0-255

operative mode
XY communication
normal
current state


wrong


Small motor communication
normal



wrong


Focus hall
normal



wrong


Color plate hall
normal



wrong


Pattern hall
normal



wrong


X optocoupler
normal



wrong


Y optocoupler
normal



wrong


Fan speed
6500


Return to the superior
▲

auxiliary neans
Calibration code 1
0-9999


total time
zero clearing



carry out


Light gun time
zero clearing



carry out


Restore the default
give tacit consent to



recover



preserve


Horizontal rotation
0-255
Zero-bit initial bits

vertical turn
0-255


focus
0-255


Prism # # 1
0-255


Prism mirror 2
0-255


Prism rotation 1
0-255


Prism rotation 2
0-255


atomization
0-255


Color combination
0-255


Fixed pattern
0-255


colour disk
0-255


stroboflash
0-255


Flash midpoint
0-255


Prism a point
0-255


Prism two points
0-255


Fog midpoint
0-255


Colorful midpoint
0-255


Return to the superior
▲

advanced setup
Check code 2
0-9999


Signal encryption
open



close


DMX velocity
0-255


DMX data packet
0-255


DMX type
0-055


DMX insulate
0-65535
A smaller value would indicate a more stable signal

Drive plate temperature
<110 Degrees>
Red appears beyond this range

Drive board is 3.3V
3.0V - 3.6V
Red appears beyond this range

Drive board: 5.0V
4.5V - 5.5V
Red appears beyond this range

Drive board 12V
10.0V - 14.0V
Red appears beyond this range

Drive board 36V
20.0V - 42.0V
Red appears beyond this range

X state
static



turn


X Hoare
normal



wrong
Show red

X-light coupling phase
0-3


X optocoupler A
40-160
Standard setting 100 shows red beyond the required range, but the panel red light does not alarm

X optocoupler B
40-160
Standard setting 100 shows red beyond the required range, but the panel red light does not alarm

X optocoupler C
40-160
Standard setting 100 shows red beyond the required range, but the panel red light does not alarm

X optocoupler D
40-160
Standard setting 100 shows red beyond the required range, but the panel red light does not alarm

X Current Angle
000-540


X drive state
normal



wrong
Show red

Y state
static



turn


Y optocoupler
normal



wrong
Show red

Y Hoare
normal



wrong
Show red

Y light coupling phase
0-3


Y optocoupler A
40-160
Red appears beyond this range

Y optocoupler B
40-160
Red appears beyond this range

Y optocoupler C
40-160
Red appears beyond this range

Y optocoupler D
40-160
Red appears beyond this range

Y Current Angle
000-250


Y drive state
normal



wrong
Show red

Return to the superior
▲

Channel level
Color hovering
0-255
Current DMX channel value

stroboflash
0-255


aiming
0-255


Fixed pattern
0-255


prism
0-255


Prism rotation
0-255


atomization
0-255


focus
0-255


Horizontal rotation
0-255


Horizontal fine-tuning
0-255


vertical turn
0-255


Vertical fine-tuning
0-255


reset
0-255


light up
0-288


XY velocity
0-255


Color disk speed
0-255


Zoom speed
0-255


pattern velocity
0-255


Return to the superior


reset
Full reset
cancel
manual reset


carry out


XY reset
cancel



carry out


Effect reset"
cancel



carry out


Return to the superior


Exit menu



16 Channel table
CH1
pigment
0--4
white light


5--9
White light + color 1


10--14
Color 1


15--19
Color # 1 + color # 2


20--24
Color 2


25--29
Color # 2 + color # # 3


30--34
Color 3


35--39
Color # 3 + color # # 4


40--44
Color 4


45-49
Color # 4 + color # # 5


50--54
Color 5


55--59
Color # 5 + color # # 6


60--64
Color 6


65--69
Color # 6 + color # # 7


70--74
Color 7


75--79
Color # 7 + color # # 8


80--84
Color 8


85--89
Color # 8 + color # # 9


90--94
Color 9


95--99
Colour 9 + color 10


100--104
Color 10


105--109
Colour 10 + color 11


110--114
Color 11


115--119
Colour 11 + color 12


120--124
Color 12


125--129
Colour 12 + color 13


130--135
white light


136--195
From fast to slow forward flowing water


196--255
From fast to slow reverse flow water
CH2
stroboflash
0-5
The light switch is closed


6--20
Open the flash


21-70
Synchronize the strobe slow to fast


71-100
Random strobe is slow to fast


101-150
Pulse strobe is slow to fast


151-190
The open pulse is slow to fast


191-230
Turn-off pulse frequency strobe is slow to fast


231-255
The light switch is opened
CH3
aiming
0-255
With 0-100% dimming
CH4
pattern
0--4
White aperture


5--9
Pattern 1


10--14
Pattern 2


15--19
Pattern 3


20--24
Pattern 4


25--29
Pattern 5


30--34
Pattern 6


35--39
Pattern 7


40--44
Pattern 8


45-49
Pattern 9


50--54
Pattern 10


55--59
Pattern 11


60--64
Pattern 12


65--69
Pattern 13


70-125
From fast to slow counterclockwise flow water


126-130
Stop running water


131-190
From slow to fast counterclockwise flow water


191-195
Pattern 1 shakes from slow to fast


196-200
Pattern 2 shakes from slow to fast


201-205
Pattern 3 shakes from slow to fast


206-210
Pattern 4 shakes from slow to fast


211-215
Pattern 5 shakes from slow to fast


216-220
Pattern 6 shakes from slow to fast


221-225
Pattern 7 shakes from slow to fast


226-230
Pattern 8 shakes from slow to fast


231-235
Pattern 9 shakes from slow to fast


236-240
Pattern 10 shakes from slow to fast


241-245
Pattern 11 shakes from slow to fast


246-250
Pattern 12 from slow to fast


251-255
Pattern 13 with a jitter ranging from slow to fast
CH5
prism
0-127
Remove the prism


128-255
Prism cut in
CH6
Prism rotation
0-127
0-400 degrees


128-189
From fast to slow reverse flow water


190-194
cease


195-255
From slow to fast forward flowing water
CH7
Reserved empty


CH8
Fog colorful
0-127



128-169
Insert atomization


170-255
Insert colorful
CH9
focus
0-255
From far to near
CH10
X axle
0-255
0-540 degrees
CH11
X axis fine-tuning
0-255
The X-axis 16bit fine-tuning channel
CH12
Y axle
0-255
0-240 degrees
CH13
Y axis fine-tuning
0-255
Y axis 16bit tuning channel
CH14
XY velocity
0-255

CH15
Reserved empty
0-255
NC
CH16
Light reset
0-99
NF


100-105
Off-bulb (5S)


106-199
NF


200-205
Open the light bulb (5S)


206-249
NF


250-255
All motor reset (5S)

Instructions for lamp installation:
This lamp can be placed horizontally, oblique hanging and upside down, oblique hanging and upside down must pay attention to the installation method. Fixed installation of lamps: before the positioning of lamps, ensure the stability of the installation site, the lamps must not fall off the support frame, and use the support frame and the safety rope for auxiliary hanging; to ensure safety. Prevent the falling and sliding of the lamps and lanterns. During the installation and debugging, the safety rope is worn and the hook screw is loose. If the hanging installation is not stable, and all the consequences of the falling, the manufacturer will not bear any responsibility.


after-sale service
pay attention to! When the lamps leave the factory, they are passed by strict quality inspection, and the packaging is in good condition. Please operate according to the instructions. Machine failure caused by human causes is not covered by the warranty.
The company provides technical advice to our clients for life.
If the product is faulty and needs to be repaired, please show the product warranty card and fill in the relevant content truthfully. At the same time, we also hope that customers can feedback the problems of the product to us in time, so as to facilitate us to improve the product in the first time